FUSE???

by Jo7Gle
  Prev :: Next
What size fuse and gauge wire would I use between my alt (MAXX 200 amp).


Replies (4)
swez on 05/20/2007 13:45:54
A 200 amp ANL fuse would be great. You will also need an ANL type fuse holder as well. (Typically 1/0 gage wire)

http://www.antonline.com/p_63110-NX_270190.htm (200A ANL fuse)

http://www.antonline.com/p_EWFH-NX_272791.htm (Fuse Holder)

Swez

Jo7Gle on 05/20/2007 13:56:53
I have a extra 250 ANl layin around. would it work ok.


swez on 05/20/2007 16:33:19
The fuse rating is based on wire gage used and the anticipated MAX current draw of a given circuit. If you do use the Maxx 200 ALT, I'd feel safer using a 200A fuse to protect the investment.

A 1/0 gage wire is able to handle about 300 A's of current. If using a slammer gage wire here, use a fuse that will protect your wires from fire.

Swez

Jo7Gle on 05/20/2007 17:00:52
Ok thanks swez